TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
FO 1001-506 Forbo Giubiasco SA Floor covering
ColoRex EC Everest (2010)
FI 1005-523 Fischer Elektro- und Beleuchtungstechnik GmbH Material sample
Powder-coated surface
Biological resistance (ISO 846)
Chemical resistance (VDI 2083 part 17)
Outgassing (VDI 2083 part 17)
FI 1005-523 Fischer Elektro- und Beleuchtungstechnik GmbH Material sample
Sealing
Biological resistance (ISO 846)
Chemical resistance (VDI 2083 part 17)
Outgassing (VDI 2083 part 17)
ED 1001-504 edding Internat. GmbH Cleanroom marker
e-8011
blue
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
ED 1001-504 edding Internat. GmbH Cleanroom marker
e-8011
green
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
ED 1001-504 edding Internat. GmbH Cleanroom marker
e-8011
red
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
BR 0605-350 BRUCHA GmbH Sheeting coverings
Ludwigstahl AG
Coil No. 011703/9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
BR 0605-350 BRUCHA GmbH Sheeting coverings
Duferco Coating S. A.
Coil No. 011385/9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
BR 0605-350 BRUCHA GmbH Sheeting coverings
ThyssenKrupp Materials Austria GmbH
Coil No. 011108 /9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
BR 0605-350 BRUCHA GmbH Sheeting coverings
US-Steel, s. r. o.
Coil No. 009876/9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
BR 0605-350 BRUCHA GmbH Sheeting coverings
Myriad SA
Coil No. 009457/9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
BR 0605-350 BRUCHA GmbH Sheeting coverings
Ludwigstahl AG
Coil No. 008383/9002
Chemical resistance (VDI 2083 part 17)
Outgassing (VOC)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean
without Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean
with Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean S
without Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean S
with Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Schlicht
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
KN 1202-589 Knauf AMF GmbH & Co. KG Coating
AMF Acoustic Range coating (white)
Chemical resistance (VDI 2083 part 17)
LE 1212-626 LEONI Kerpen GmbH MegaLine D1-20 S/U superflex 4P 11Y
SPICE Code 10124
Chemical resistance (VDI 2083 part 17)
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1)
Riboflavin test (VDMA information leaflet)
RO 1212-628 Rockwool B.V., Rockfon (NL) Medicare Block
Prototype
Chemical resistance (VDI 2083 part 17)
12347
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years