TESTED DEVICE®
Report No. | Manufacturer | Product Name | Subject of Test (Result) |
---|---|---|---|
WE 0112-252 | WEZ Kunststoffwerk AG | Stash box type 63.4313.097.999 | ESD behaviour (DIN EN 61340-5-1) Outgassing (VOC) |
WE 0112-252 | WEZ Kunststoffwerk AG | Slot wall type 63.3518.000.999 | ESD behaviour (DIN EN 61340-5-1) Outgassing (VOC) |
WE 0112-252 | WEZ Kunststoffwerk AG | Insert box type 63.1309.055.399 | ESD behaviour (DIN EN 61340-5-1) Outgassing (VOC) |
SI 0311-298 | Sika AG | Sealant Sikaflex-521 UV | Outgassing (VOC) |
SI 0311-298 | Sika AG | Sealant Sikaflex-221 RLT | Outgassing (VOC) |
SI 0311-298 | Sika AG | Sealant Sikasil-N plus | Outgassing (VOC) |
OW 0107-246 | Odenwald Faserplattenwerk GmbH | Ceiling system OWAcoustic® clean 64/14/0 | Cleanability (VDI 2083 part 17) Outgassing (VOC) Particle emission (VDI 2083 part 9.1) (ISO Class 4) |
OW 0107-246 | Odenwald Faserplattenwerk GmbH | Ceiling system OWAcoustic® clean 64/18/0 | Cleanability (VDI 2083 part 17) Outgassing (VOC) Particle emission (VDI 2083 part 9.1) (ISO Class 4) |
LI 0502-319 | Lindab GmbH | EPDM seal GI for cleanroom components | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | EPDM seal NO for cleanroom components | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | EPDM seal TR for cleanroom components | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | Cleanroom components flap socket PP | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | Cleanroom components Lindab LDB | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | Cleanroom components Lindtec | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | Cleanroom components zinc repair paint ES | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
LI 0502-319 | Lindab GmbH | Cleanroom components zinc repair paint OS | Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Outgassing (VOC) |
GE 0802-427 | Gerflor Mipolam GmbH | Floor covering MIPOLAM BIOCONTROL MIPOLAM BIOCONTROL | Biological cleanability (VDI 2083 part 17) Biological resistance (ISO 846) Chemical resistance (VDI 2083 part 17) Cleanability (VDI 2083 part 17) ESD behaviour (DIN EN 61340-5-1) Outgassing (VOC) Particle emission (VDI 2083 part 17) (ISO Class 4) |
GE 0211-280 | Gerflor Mipolam GmbH | Floor covering Technic EL 5 vs. PA6 | Chemical resistance (VDI 2083 part 17) Expertise Outgassing (VOC) Particle emission (VDI 2083 part 9.1) (ISO Class 3) Particle emission (VDI 2083 part 9.1) (ISO Class 4) Particle emission (VDI 2083 part 9.1) (ISO Class 5) |
GE 0211-280 | Gerflor Mipolam GmbH | Floor covering GTI Prisma vs. PA6 | Chemical resistance (VDI 2083 part 17) Cleanability (VDI 2083 part 17) Expertise Outgassing (VOC) Particle emission (VDI 2083 part 9.1) (ISO Class 4) Particle emission (VDI 2083 part 9.1) (ISO Class 6) |
FE 0705-402 | Festo AG & Co. KG | Pneumatic cylinder MH 1 | EDX analysis Outgassing (Inorganic) Outgassing (VOC) Particle emission (VDI 2083 part 9.1) (ISO Class 3) |
Filters
Text
Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*
- All ISO Classes (46 Hits)
- ISO Class 2 or better (1 Hits)
- ISO Class 3 or better (5 Hits)
- ISO Class 4 or better (12 Hits)
- ISO Class 5 or better (15 Hits)
- ISO Class 6 or better (16 Hits)
- ISO Class 7 or better (17 Hits)
- ISO Class 8 or better (17 Hits)
- ISO Class 9 or better (17 Hits)
Subject Of Test
- All (1496 Hits)
- Ab- / Desorption kinetic (VDI 2083 part 20 draft) (56 Hits)
- Absorption behaviour (DIN EN ISO 9073-6) (2 Hits)
- Acustic power (ISO 3741) (1 Hits)
- Air flow velocity (7 Hits)
- Air flow visualisation (7 Hits)
- Air permeability (1 Hits)
- Airborne Siloxanes (ISO 16017-1) (1 Hits)
- Biological cleanability (VDI 2083 part 17) (5 Hits)
- Biological resistance (ISO 846) (131 Hits)
- Chemical resistance (VDI 2083 part 17) (133 Hits)
- Cleanability (VDI 2083 part 17) (23 Hits)
- Cleaning performance - particles (VDI 2083 part 17) (5 Hits)
- Computational Fluid Dynamics (CFD) (1 Hits)
- Contamination residues (2 Hits)
- EDX analysis (1 Hits)
- Electrical Resistance (acc. to DIN EN 61340-2-3, DIN EN 61340-3-2 and DIN EN 61340-3-1) (4 Hits)
- ESD behaviour (DIN EN 61340-5-1) (53 Hits)
- ESD behaviour (SEMI E78) (13 Hits)
- Expertise (92 Hits)
- Extractable organic matter (IEST-RP-CC005.3) (1 Hits)
- Feasibility study (2 Hits)
- Gravimetric analysis (17 Hits)
- Isolation factor (1 Hits)
- Leakage testing (3 Hits)
- Microbicidity (ISO 22196) (16 Hits)
- Outgassing (Inorganic) (1 Hits)
- Outgassing (VDI 2083 part 17) (198 Hits)
- Outgassing (VOC) (46 Hits)
- Particel emission (ISO 14644 part 14) (408 Hits)
- Particle emission (VDI 2083 part 17) (178 Hits)
- Particle emission (VDI 2083 part 9.1) (512 Hits)
- Particle per wafer and pass (PWP) (3 Hits)
- Particles (airborne) (8 Hits)
- Particles (sedimented) (5 Hits)
- Pressure conditions (7 Hits)
- PWIS – paint wetting impairment substances (PV 3.10.7) (1 Hits)
- Raman analysis (1 Hits)
- Resistance to corrosion (NaCl) (1 Hits)
- Riboflavin test (VDMA information leaflet) (95 Hits)
- Thin film contamination (4 Hits)
- Training (1 Hits)
Categories
- All (46 Hits)
- Cleanroom Facilities (18 Hits)
- Working Place and Operator (6 Hits)
- Materials (20 Hits)
- Process Equipment (2 Hits)