TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
ZO 1608-844 ZORN Maschinenbau GmbH Zorn linear axis
ZLAG1-100-Z
Aluminium anodized
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
TO 2211-1362 TOX PRESSOTECHNIK GmbH & Co. KG EXe-K 030.555.300.002 ElectricPowerDrive
manufacturing date: 5/2022
material: Aluminum anodized
Particel emission (ISO 14644 part 14) (ISO Class 5)
SC 1506-768 Schneider Electric Automation GmbH (Lahr) Linear unit Lexium TAC41SBC0500A1BS
Stroke: 500 mm
ID number: 0071001001661
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
SC 1506-768 Schneider Electric Automation GmbH (Lahr) Linear unit Lexium TAC41SBC0100A1BS
Stroke: 100 mm
ID number: 0071001001660
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 50
manufacturing date: 11/7/2022
weight: 12.54 kg
Particel emission (ISO 14644 part 14) (ISO Class 4)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 65
manufacturing date: 11/7/2022
weight: 18.96 kg
Particel emission (ISO 14644 part 14) (ISO Class 2)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 80
manufacturing date: 10/31/2022
weight: 35 kg
Particel emission (ISO 14644 part 14) (ISO Class 7)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 110
manufacturing date: 11/3/2022
weight: 54.70 kg
Particel emission (ISO 14644 part 14) (ISO Class 5)
RO 1505-764 ROLLON GmbH Cleanroom unit ONE80
Travel length: 2200 mm
power unit: KOLLMORGEN Seidel 6SM57M-3000 | gearing: BONFIGLIOLI MP 080.1.4.15‘.19.40.80.100.CR
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
RK 1404-704 RK Rose+Krieger GmbH Linear unit without extraction system
RK DuoLine S60 Clean | Stroke: 1500 mm
Drive: SMHA60601.45112ID65-404
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
RK 1404-704 RK Rose+Krieger GmbH Linear unit with extraction system
RK DuoLine S60 Clean | Stroke: 1500 mm
Drive: SMHA60601.45112ID65-404
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
RK 1404-704 RK Rose+Krieger GmbH Linear unit with extraction system
RK DuoLine Z80 Clean | Stroke: 2000 mm
Drive: SMH60601.45112ID65-400 | Gear: PLE 60
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
RK 1404-704 RK Rose+Krieger GmbH Linear unit without extraction system
RK DuoLine Z80 Clean | Stroke: 2000 mm
Drive: SMH60601.45112ID65-400 | Gear: PLE 60
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
RK 1404-704 RK Rose+Krieger GmbH Linear unit with extraction system
RK DuoLine S80 Clean | Stroke: 2000 mm
Drive: SMHA60601.45112ID65-400
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
RK 1404-704 RK Rose+Krieger GmbH Linear unit without extraction system
RK DuoLine S80 Clean | Stroke: 2000 mm
Drive: SMHA60601.45112ID65-400
Particle emission (VDI 2083 part 9.1) (ISO Class 8)
RK 1404-704 RK Rose+Krieger GmbH Linear unit with extraction system
RK DuoLine Z60 Clean | Stroke: 2000 mm
Drive: SMH60601.45112ID65-400 | Gear: PLE 60
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
RK 1404-704 RK Rose+Krieger GmbH Linear unit without extraction system
RK DuoLine Z60 Clean | Stroke: 2000 mm
Drive: SMH60601.45112ID65-400 | Gear: PLE 60
Particle emission (VDI 2083 part 9.1) (ISO Class 8)
RK 1404-704 RK Rose+Krieger GmbH Linear unit without extraction system
RK DuoLine R60 Clean | Stroke: 1780 mm
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
LA 1306-649 LANG GmbH & Co. KG Controller system
L-Step Express 19'' 480VA
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
LA 1306-649 LANG GmbH & Co. KG Linear axis
CTV 110-1616-ISO7-510-L-0-1
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years