TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
RO 1505-764 ROLLON GmbH Cleanroom unit ONE80
Travel length: 2200 mm
power unit: KOLLMORGEN Seidel 6SM57M-3000 | gearing: BONFIGLIOLI MP 080.1.4.15‘.19.40.80.100.CR
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
RO 1706-917 RK Rose+Krieger GmbH Multilift II-400-Clean
Baujahr: 2017; Gewicht: 11,5 kg
Einbaulänge: 603 mm; Hub: 400 mm; max. Zug- / Druckkraft: 3000 N; max. Hubgeschwindigkeit: 8 mm/s
Particel emission (ISO 14644 part 14) (ISO Class 4)
RO 1706-917 RK Rose+Krieger GmbH Multilift II-400-Clean mit Absaugung
Baujahr: 2017; Gewicht: 11,5 kg
Einbaulänge: 603 mm; Hub: 400 mm; max. Zug- / Druckkraft: 3000 N; max. Hubgeschwindigkeit: 8 mm/s
Particel emission (ISO 14644 part 14) (ISO Class 4)
RO 1710-959 Robtools SMT Sp. z o.o. ESD vinyl chair for clean room RS-KESD/CR 039170500001
Herstellungsdatum: 15/5/2017
black vinyl
Particel emission (ISO 14644 part 14) (ISO Class 5)
RO 1808-1064 ROCKWOOL International A/S, ROCKFON (DK) Ceiling panel MediCare Block
Dimension: 440 x 300 x 25 mm; Color: White
Manufacturing date: 9/6/2018
Chemical resistance (VDI 2083 part 17)
RO 1808-1064 ROCKWOOL International A/S, ROCKFON (DK) Ceiling system MediCare Block
Dimension: 600 x 600 x 25 mm; Color: White
Manufacturing date: 3/31/2017
Particel emission (ISO 14644 part 14) (ISO Class 1)
RO 1808-1064 ROCKWOOL International A/S, ROCKFON (DK) Ceiling system MediCare Air
Dimension: 600 x 600 x 25 mm; Color: White
Manufacturing date: 3/2/2018
Particel emission (ISO 14644 part 14) (ISO Class 2)
RO 1808-1064 ROCKWOOL International A/S, ROCKFON (DK) Ceiling system MediCare Plus
Dimension: 600 x 600 x 20 mm; Color: White
Manufacturing date: 5/27/2018
Particel emission (ISO 14644 part 14) (ISO Class 2)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 50
manufacturing date: 11/7/2022
weight: 12.54 kg
Particel emission (ISO 14644 part 14) (ISO Class 4)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 65
manufacturing date: 11/7/2022
weight: 18.96 kg
Particel emission (ISO 14644 part 14) (ISO Class 2)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 80
manufacturing date: 10/31/2022
weight: 35 kg
Particel emission (ISO 14644 part 14) (ISO Class 7)
RO 2211-1366 Rollon S.p.A. Linear unit ONE 110
manufacturing date: 11/3/2022
weight: 54.70 kg
Particel emission (ISO 14644 part 14) (ISO Class 5)
RY 1307-661 Rychiger AG R&D Sealer RD06
(Stanz- und Siegelmaschine)
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
SA 1011-538 EASYDOING OY / SALLI SYSTEMS Chair
Salli Swing Esd
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
SA 1105-551 SAMICK PRECISION IND. CO., Ltd Bearing
LME25UU-RESIN
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
SA 1105-551 SAMICK PRECISION IND. CO., Ltd Bearing
LME25UU-STEEL
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
SA 1105-551 SAMICK PRECISION IND. CO., Ltd Bearing
LME8UU
Outgassing (VDI 2083 part 17)
SA 1105-551 SAMICK PRECISION IND. CO., Ltd Bearing
LMES10UU
Outgassing (VDI 2083 part 17)
SA 1105-551 SAMICK PRECISION IND. CO., Ltd Bearing
LMES25UU
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
SA 1706-916 EASYDOING OY / SALLI SYSTEMS Salli Swing ESD, saddle chair (Chair)
manufacturing date: 9/5/2017
black
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
1515253545574
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years