TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
GE 0802-427 Gerflor Mipolam GmbH Floor covering
MIPOLAM BIOCONTROL
MIPOLAM BIOCONTROL
Biological cleanability (VDI 2083 part 17)
Biological resistance (ISO 846)
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
ESD behaviour (DIN EN 61340-5-1)
Outgassing (VOC)
Particle emission (VDI 2083 part 17) (ISO Class 4)
FA 0811-460 FANUC Robotics Europe S.A. Robot
LR Mate 200iC/5C
12
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years