TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
ME 0801-423 Memmert GmbH + Co. KG Universal oven
UFP 500
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
MS 0806-436 Microtec Systems GmbH Screwdriver system
ETD M25 AVB
(vacuum)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
SO 0806-440 Sommer-automatic GmbH Gripper
RMSF 40S-D2
TR 0805-433 Trilux GmbH & Co. KG Lighting system
FIDESCA SD
series
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
TR 0805-433 Trilux GmbH & Co. KG Lighting system
FIDESCA PM
series
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
GO 0810-448 W.L. Gore & Associates GmbH (USA) Cable system
Flat Cable Assembly TK 31540-01
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
GO 0810-448 W.L. Gore & Associates GmbH (USA) Cable system
2 layers of GSC-06-6038-00 planar cables
Kette: Igus E6
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.