Report No. | Manufacturer | Product Name | Subject of Test (Result) |
---|---|---|---|
SI 1008-533 | Sika AG | Floor covering Sikafloor-21 N PurCem | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Sealant Sikasil-Pool | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Sealant Sikasil-DW | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Sealant Sikaflex AT-Connection | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-304 W | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikagard-183 W CR | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-263 SL | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-264 | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-235 ESD | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-269 ECF CR | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-269 CR | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-266 ECF CR | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-266 CR | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-169 | Biological resistance (ISO 846) |
SI 1008-533 | Sika AG | Floor covering Sika-CompactFloor | Biological resistance (ISO 846) Particle emission (VDI 2083 part 17) (ISO Class 5) |
SI 1008-533 | Sika AG | Floor covering Sika-DecoFlake | Biological resistance (ISO 846) Particle emission (VDI 2083 part 17) (ISO Class 4) |
SI 1008-533 | Sika AG | Floor covering Sika-DecoFloor | Biological resistance (ISO 846) Particle emission (VDI 2083 part 17) (ISO Class 4) |
SI 1008-533 | Sika AG | Floor covering Sika-ComfortFloor Decorative | Biological resistance (ISO 846) Particle emission (VDI 2083 part 17) (ISO Class 1) |
SI 1008-533 | Sika AG | Floor covering Sika-ComfortFloor | Biological resistance (ISO 846) Particle emission (VDI 2083 part 17) (ISO Class 2) |
SI 1008-533 | Sika AG | Floor covering Sikafloor-390 AS | Biological resistance (ISO 846) Outgassing (VDI 2083 part 17) Particle emission (VDI 2083 part 17) (ISO Class 4) |
Filters
Text
Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*
- All ISO Classes (73 Hits)
- ISO Class 1 (10 Hits)
- ISO Class 2 or better (16 Hits)
- ISO Class 3 or better (19 Hits)
- ISO Class 4 or better (24 Hits)
- ISO Class 5 or better (31 Hits)
- ISO Class 6 or better (43 Hits)
- ISO Class 7 or better (45 Hits)
- ISO Class 8 or better (45 Hits)
- ISO Class 9 or better (45 Hits)
Subject Of Test
- All (73 Hits)
- Air permeability (1 Hits)
- Biological cleanability (VDI 2083 part 17) (1 Hits)
- Biological resistance (ISO 846) (27 Hits)
- Chemical resistance (VDI 2083 part 17) (8 Hits)
- Cleanability (VDI 2083 part 17) (4 Hits)
- ESD behaviour (DIN EN 61340-5-1) (1 Hits)
- Expertise (8 Hits)
- Outgassing (VDI 2083 part 17) (10 Hits)
- Outgassing (VOC) (3 Hits)
- Particle emission (VDI 2083 part 17) (10 Hits)
- Particle emission (VDI 2083 part 9.1) (42 Hits)
- Particle per wafer and pass (PWP) (1 Hits)
Categories
- All (73 Hits)
- Cleanroom Facilities (42 Hits)
- Automation Components (17 Hits)
- Working Place and Operator (5 Hits)
- Materials (1 Hits)
- Energy Supply (8 Hits)