TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
FR 0302-287 nora systems GmbH Floor covering
noraplan sentica ed, recipe 948
EC 0912-502 Saint-Gobain Ecophon AB Decke system
Hygiene Advance A C3
Cleanability (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
RO 1212-627 Rockwool B.V., Rockfon (NL) Medicare Block
Prototype
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (film curtain)
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (strip curtain)
Expertise
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1611-855 Planex Technik in Textil GmbH Cleanroom curtain CleanTex Streifenvorhang
PVC (antistatisch ausgerüstet) Transparent
Streifen: Breite 300mm, Stärke 1mm, Überlappung 50mm
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1611-855 Planex Technik in Textil GmbH Reinraumvorhang CleanTex Folienvorhang
PVC (antistatisch ausgerüstet) Transparent
Expertise
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAtecta® LO
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAlux® 64/1/N
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/12/0
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/14/0
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/18/0
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0504-322 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic®
Universal
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
KN 0904-479 Knauf AMF GmbH & Co. KG Ceiling system
Thermatex Thermofon
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
KN 0904-479 Knauf AMF GmbH & Co. KG Ceiling system
Thermatex Plain
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
HI 1702-888 Hilti Entwicklungsgesellschaft mbH Hilti Firestop Block
CFS-BL
Red
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
KG 0012-227 Gilgen Door Systems AG Sliding door system
SLM
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
GE 0211-280 Gerflor Mipolam GmbH Floor covering
Technic EL 5
vs. PA6
Chemical resistance (VDI 2083 part 17)
Expertise
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
GE 0211-280 Gerflor Mipolam GmbH Floor covering
GTI Prisma
vs. PA6
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Expertise
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
CA 0102-230 Caparol Farben Lacke Bautenschutz GmbH & Co Vertriebs KG Floor covering
Disboxid 472
AS-Deckschicht
ESD behaviour (DIN EN 61340-5-1)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 7)
12
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years