TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
MA 1502-748 Mapei S.p.A. Floor covering
MAPECOAT I62 W
Surface smooth
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 17) (ISO Class 5)
MA 1502-748 Mapei S.p.A. Floor covering
MAPEFLOOR I390 EDF
Surface smooth
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 17) (ISO Class 3)
ME 1811-1085 Memmert GmbH + Co. KG Constant climate chamber HPP1060
Color: stainless steel
Manufacturing date: 9/2018
Particel emission (ISO 14644 part 14) (ISO Class 5)
NO 1405-708 NORD RESINE SPA Floorcovering
NORDPUR SW
(GREY)
Particle emission (VDI 2083 part 17) (ISO Class 5)
NA 1407-717 Nanten Oy Floor covering
Nanten SL Epoxy Coating
Biological resistance (ISO 846)
Particle emission (VDI 2083 part 17) (ISO Class 1)
NU 1310-671 Nuplex Construction Products Floorcovering
Sureshield
Color: Natural Gold
Biological resistance (ISO 846)
Chemical resistance (VDI 2083 part 17)
Microbicidity (ISO 22196)
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 17) (ISO Class 4)
Riboflavin test (VDMA information leaflet)
OW 0504-322 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic®
Universal
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/18/0
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/14/0
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAcoustic® clean
64/12/0
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAlux® 64/1/N
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 0107-246 Odenwald Faserplattenwerk GmbH Ceiling system
OWAtecta® LO
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
PH 1011-536 PHILIPS LIGHTING B. V. Luminaire
Luminaire series TBS
Expertise
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PH 1201-586 Philips Lighting B.V. Luminaire
Cleanroom LED
CR434B LED88/840 SQR
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
PH 1201-586 Philips Lighting B.V. Luminaire
Cleanroom LED
CR434B LED88/840 RECT
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PH 1802-1006 Philips Lightning Cleanroom CR434B LED 48/840 PSD W60L60
Manufacturing date: 12/6/2017
Particel emission (ISO 14644 part 14) (ISO Class 1)
PH 1802-1006 Philips Lightning Cleanroom CR434B LED 88/830 PSD W30L120
Manufacturing date: 12/6/2017
Particel emission (ISO 14644 part 14) (ISO Class 1)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (film curtain)
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (strip curtain)
Expertise
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1611-855 Planex Technik in Textil GmbH Cleanroom curtain CleanTex Streifenvorhang
PVC (antistatisch ausgerüstet) Transparent
Streifen: Breite 300mm, Stärke 1mm, Überlappung 50mm
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
1234568
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*