TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
VA 1401-690 VAT Vakuumventile AG Transfer valve
Valve-575654 V1 (Prototype)
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
VA 0907-492 Von Ardenne Anlagentechnik GmbH Cable Guiding System
Power drag chain, designed to application inside PVD and PECVD reactor chambers
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
GO 1504-757 W.L. Gore & Associates GmbH (Pleinfeld) Low Outgassing Trackless Cable
GKT-FTFH-V01-A
(prototype)
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-02-01
Charge number 5621789-2, 5621789-1
Manufacturing date 30/6/2017; Color White
Particel emission (ISO 14644 part 14) (ISO Class 1)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-02-02
Charge number 5621790-2, 5621790-1
Manufacturing date 28/6/2017; Color White
Particel emission (ISO 14644 part 14) (ISO Class 1)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-02-03
Charge number 5621791-2, 5621791-1
Manufacturing date 29/6/2017; Color White
Particel emission (ISO 14644 part 14) (ISO Class 1)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-03-04
Charge number 56210718
Color White
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-03-05
Charge number 56210738
Color White
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-03-07
Color White
Charge number #787
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-03-08
Color White
Charge number #791
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) Anti-ESD Trackless Cable GKT-FTFH-03-09
Color White
Charge number #792
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) GORE Low Charging Trackless Cable GKT-FTFH-03-00 #847
Color White
Charge number #847
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) GORE Low Charging Trackless Cable GKT-FTFH-03-00 #845
Color White
Charge number #845
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 1708-940 W.L. Gore & Associates GmbH (Pleinfeld) GORE Low Charging Trackless Cable GKT-FTFH-03-00 #811
Color White
Charge number #811
Particel emission (ISO 14644 part 14) (ISO Class 3)
GO 0810-448 W.L. Gore & Associates GmbH (USA) Cable system
Flat Cable Assembly TK 31540-01
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
GO 0810-448 W.L. Gore & Associates GmbH (USA) Cable system
2 layers of GSC-06-6038-00 planar cables
Kette: Igus E6
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
WE 1801-997 Werma Signaltechnik GmbH & Co. KG Clean SIGN BM 695.X10.55 signal tower
Clean SIGN BM
manufacturing date 18/1/2018
Particel emission (ISO 14644 part 14) (ISO Class 2)
WE 1301-634 Werma Signaltechnik GmbH & Co. KG Signal light
CleanSIGN
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
WE 0910-498 Werma Signaltechnik GmbH & Co. KG Signal Tower
CleanSIGN
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
YA 1205-598 YASKAWA Europe GmbH MOTOMAN roboter MPP3
(Delta kinematic)
Particle emission (VDI 2083 part 9.1) (ISO Class 1)
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years