TESTED DEVICE®

Report No.downup Manufacturerdownup Product Namedownup Subject of Test (Result)downup
AR 0701-375 Armstrong Metalldecken AG Ceiling system
Q-Clip
Particle emission (VDI 2083 part 9.1) (ISO Class 3)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean
without Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean
with Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean S
without Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 5)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Thermaclean S
with Acryl
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Schlicht
Chemical resistance (VDI 2083 part 17)
Cleanability (VDI 2083 part 17)
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
AM 0112-253 AMF Mineralplatten GmbH Betriebs KG Ceiling system
type Kombimetall
Outgassing (VOC)
Particle emission (VDI 2083 part 9.1) (ISO Class 6)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (film curtain)
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
PL 1109-575 Planex Technik in Textil GmbH Cleanroom curtain
CleanTex
prototype (strip curtain)
Expertise
Outgassing (VDI 2083 part 17)
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
OW 1105-554 Ceiling
OWAtecta cleanRoom
system L / system U
Expertise
Particle emission (VDI 2083 part 9.1)
Particle emission (VDI 2083 part 9.1) (ISO Class 4)
OW 1003-518 Odenwald Faserplattenwerk GmbH Ceiling system
OWAtecta system S 33 and S 45
Particle emission (VDI 2083 part 9.1)
KN 1203-591 Knauf Insulation GmbH ceiling system
Heradesign soft
Particle emission (VDI 2083 part 9.1)
KN 1202-589 Knauf AMF GmbH & Co. KG Ceiling system
THERMATEX Acoustic
Particle emission (VDI 2083 part 9.1)
KN 1202-589 Knauf AMF GmbH & Co. KG Ceiling system
THERMATEX Alpha
Particle emission (VDI 2083 part 9.1)
KN 1202-589 Knauf AMF GmbH & Co. KG Ceiling system
THERMATEX Thermaclean S
Particle emission (VDI 2083 part 9.1)
KN 1202-589 Knauf AMF GmbH & Co. KG Ceiling system
THERMATEX Alpha ONE
Particle emission (VDI 2083 part 9.1)
OW 1003-518 Odenwald Faserplattenwerk GmbH Ceiling system
OWAtecta S 22
with lighting OWA-Opal / OWA-Opa E
Particle emission (VDI 2083 part 9.1)
RO 1212-627 Rockwool B.V., Rockfon (NL) Medicare Block
Prototype
Particle emission (VDI 2083 part 9.1) (ISO Class 2)
DU 1410-727 Dutch Microwave Absorber Solutions BV (DMAS) Microwave absorber MT45
Batch number: 2608
Particle emission (VDI 2083 part 9.1)
DU 1410-727 Dutch Microwave Absorber Solutions BV (DMAS) Hybrid absorber HT45
Batch number: 2165
Particle emission (VDI 2083 part 9.1)
*Extract from VDI 2083 Part 9.1: "This guidline provides definitions of the terms "compatibility with the required cleanliness" and "cleanroom compatibility" and, based on these definitions, the classification and procedures serving to establish the suitability of equipment and air-handling components for use in environments whose air cleanliness and other parameters are assessed in accordance with technical rules (e.g. ISO 14644-1). For the purpose of this guideline, the classification is based on the particle emission.

Filters

Text


Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*

Subject Of Test

Categories

Years