TESTED DEVICE®

No image available!

Company

Helukabel GmbH
 
Dieselstraße 8 -12
71282 Hemmingen

Contact Person

Oliver Schmitz
Phone +49 7150 9209 786
Email oliver.schmitz@helukabel.de
Website www.helukabel.de

Test Object

Kabelserie
CLEANFLEX-HF
Q-Id HE 1204-594
Year 2012
Comments
Category Cable Systems

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Particle emission (VDI 2083 part 9.1) reference energy chain igus E3.15.060.032.0
traveling distance 820 mm
bending radius 50 mm
cable length 1070; 1020; 1050 mm
velocity 0.5; 0.1; 0.2 m/s
acceleration 1.0; 2.0; 4.0 m/s²
ISO 14644-1 / ISO Class 3
US FED 209E / US Class 1
certificate 1 en
(13-07-17)
statement 1 en
(13-07-17)
Outgassing (VDI 2083 part 17) temperature 23 °C
SER (TVOC) / < 00000000082 g/m²s
14644-8 / ISO-AMC Class (TVOC) <-9.1
certificate 1 en
(13-07-17)
statement 1 en
(13-07-17)
temperature 90 °C
SER (TVOC) / <0000000049 g/m²s
14644-8 / ISO-AMC Class (TVOC) tested