Subject of Test | Parameter | Assessment for / Results | Documents (valid to) |
Particles (airborne)
| Operating pressure: 6 bar Volume flow: 14.4 l/min Switching frequency: 3 Hz Sampeling time per measurement: 24 h Measurement: on new valve cycles | Average number: | / | 78 particles ≥ 0.1µm | Standard deviation: | / | ± 135 particles ≥ 0.1µm | | certificate
1
en
(05-08-20)
statement
1
en
(05-08-20)
|
Operating pressure: 6 bar Volume flow: 14.4 l/min Switching frequency: 3 Hz Sampeling time per measurement: 24 h Measurement: after 1 million cycles | Average number: | / | 705 particles ≥ 0.1µm | Standard deviation: | / | ± 353 particles ≥ 0.1µm | |
Operating pressure: 6 bar Volume flow: 14.4 l/min Switching frequency: 3 Hz Sampeling time per measurement: 24 h Measurement: after 5 million cycles | Average number: | / | 1325 particles ≥ 0.1µm | Standard deviation: | / | ± 613 particles ≥ 0.1µm | |
Operating pressure: 6 bar Volume flow: 14.4 l/min Switching frequency: 3 Hz Sampeling time per measurement: 24 h Measurement: after 12 million cycles | Average number: | / | 1368 particles ≥ 0.1µm | Standard deviation: | / | ± 567 particles ≥ 0.1µm | |
Contamination residues
| Test parameters: Siehe Bericht / see report | | certificate
1
en
(05-08-20)
statement
1
en
(05-08-20)
|