TESTED DEVICE®

No image available!

Company

icotek GmbH
 
Bischof-von-Lipp-Str. 1
73569 Eschach

Contact Person

Hubert Jahnke
Phone +49 7175 9238067
Email jahnke@icotek.com
Website https://www.icotek.com/

Test Object

ICODUR-PA 1.62 black
Q-Id IC 2104-1222
Year 2021
Comments Manufacturing date: 12/2020 Color: Black Article number: 2000000108.600/601
Category Wall / Ceiling / Floor

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Outgassing (VDI 2083 part 17)
Contaminant Category (x) / VOC
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / < - 9.6
certificate 1 en
(09-07-26)
statement 1 en
(09-07-26)
Contaminant Category (x) / SVOC
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / < - 9.6
Contaminant Category (x) / Amines
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / -
Contaminant Category (x) / Organophospates
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / -
Contaminant Category (x) / Siloxanes
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / -
Contaminant Category (x) / Phthalates
SERa 23 °C / < 2.8 x 10^ - 10 g/m²s
ISO ACCm Class (x) based on 23 °C / -