Subject of Test | Parameter | Assessment for / Results | Documents (valid to) |
Particel emission (ISO 14644 part 14)
| fatigue stress (seat): 1200 N fatigue stress (back): - N frequency: 12 /min | ISO 14644-1 | / | ISO Class 5 | | certificate
1
de
(15-08-26)
statement
1
de
(15-08-26)
|
fatigue stress (seat): - N fatigue stress (back): 350 N frequency: 12 /min | ISO 14644-1 | / | ISO Class 4 | |
fatigue stress (seat): 1200 N fatigue stress (back): 350 N frequency: 12 /min | ISO 14644-1 | / | ISO Class 5 | |
ESD behaviour (DIN EN 61340-5-1)
| Measuring points: Rückenlehne Test voltage: 10 V Average resistance to ground point (Rgp): 2,0 x 10^5 Ω | | certificate
1
de
(15-08-26)
statement
1
de
(15-08-26)
|
Measuring points: Sitzfläche Punkt 1 Test voltage: 10 V Average resistance to ground point (Rgp): 1,9 x 10^5 Ω | |
Measuring points: Sitzfläche Punkt 2 Test voltage: 10 V Average resistance to ground point (Rgp): 1,8 x 10^5 Ω | |
Measuring points: Sitzfläche Punkt 3 Test voltage: 10 V Average resistance to ground point (Rgp): 3,3 x 10^5 Ω | |