TESTED DEVICE®

No image available!

Company

Tarkett AB
 
Ekenäsvägen 1
37281 Ronneby

Contact Person

Per Johansson
Phone +46 457 71249
Email per.johansson@tarkett.com
Website www.tarkett.com

Test Object

Floor covering
Primo Premium
Q-Id TA 1206-603
Year 2012
Comments Batch Number: 1850706 Production Date: 13-JUN-12
Category Wall / Ceiling / Floor

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Particle emission (VDI 2083 part 17) reel-on-disc test
counter specimen PA6
single measuring track 250 mm
velocity 150 mm/s
normal force 300 N
ISO 14644-1 / ISO Class 3
US FED 209E / US Class 1
EC-GMP Annex 1 (in Betrieb) / GMP Class A
certificate 1 en
certificate 2 en
statement 1 en
statement 2 en
Outgassing (VDI 2083 part 17) temperature 23 °C
SER (siloxane) / - g/m²s
SER (amine) / - g/m²s
SER (organophosphate) / - g/m²s
SER (phthalate) / - g/m²s
SER (VOC) / 6.1E-9 g/m²s
14644-8 / ISO-AMC Class (VOC) -8.2
certificate 1 en
statement 1 en
temperature 90 °C
SER (siloxane) / 9.2E-9 g/m²s
SER (amine) / - g/m²s
SER (organophosphate) / - g/m²s
SER (phthalate) / - g/m²s
SER (VOC) / - g/m²s
14644-8 / ISO-AMC Class (VOC) -