TESTED DEVICE®

No image available!

Company

IL SAN ELECTRIC WIRE Co., Ltd.
 
34-32, Sambong-gil 164beon-gil Geumwang-eup, Eumseong-gun
369-906 Chungcheongbuk-do

Contact Person

KyoungHyoun Song
Phone +82-31-333-9777
Email kyounghyoun.song@cleanmanufacturing.fraunhofer.de
Website

Test Object

DI-Flex 101923 cable series
Tested objects: DI-Flex 101923-2, DI-Flex 101923-4, DI-Flex 101923-6
Manufacturing date: 5/14/2018
Q-Id IL 1806-1051
Year 2018
Comments
Category Cable Systems

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Particel emission (ISO 14644 part 14) bending radius: 85 mm
cable length: 820 mm
velocity: 0,5 | 1,0 | 2,0 m/s
acceleration: 1,0 | 2,0 | 4,0 m/s²
ISO 14644-1 / ISO Class 2
certificate 1 en
(18-07-23)
QLogo 1 en
(18-07-23)
QLogo 2 en
(18-07-23)
statement 1 en
(18-07-23)