TESTED DEVICE®

No image available!

Company

Tsubakimoto Chain Co.
 
1-1-3, Kannabidai, Kyotanabe,
610-0380 Kyoto

Contact Person

Yasutaka Tanaka
Phone +81 774 64-5061
Email yasutaka.tanaka@gr.tsubakimoto.co.jp
Website

Test Object

Tsubaki Cleanveyor 1 layer
Color White
Manufacturing date 5/28/2019
Q-Id TS 1908-1135
Year 2019
Comments
Category Cable Systems

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Particel emission (ISO 14644 part 14) reference energy chain igus: igus E3.15.060.032.0
bending radius: 70 mm
stroke length 820 mm
Parameter Set 1 v1 = 0.5 m / s; a1 = 1.0 m / s2
Parameter Set 2 v2 = 1.0 m / s; a2 = 2.0 m / s2
Parameter Set 3 v3 = 2.0 m / s; a3 = 4.0 m / s2
ISO 14644-1 / ISO Class 1
certificate 1 en
(15-10-24)
QLogo 1 en
(15-10-24)
QLogo 2 en
(15-10-24)
statement 1 en
(15-10-24)