TESTED DEVICE®

No image available!

Company

Roche Diagnostics GmbH
 
Sandhofer Straße 116
68305 Mannheim

Contact Person

Sascha Dell
Phone +49 621 759 1276
Email sascha.dell@roche.com
Website www.roche.de

Test Object

Floor covering
MP2L stoneware tile
Q-Id RO 1608-852
Year 2016
Comments
Category Wall / Ceiling / Floor

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Chemical resistance (VDI 2083 part 17) immersion method (ISO 2812-1)
Formalin 37% / excellent
Ammoniac 25% / excellent
Hydrogen peroxide 30% / excellent
Sulphuric acid 5% / excellent
Phosphoric acid 30% / excellent
Peracetic acid 15% / excellent
Hydrochloric acid 5% / excellent
Isopropanol 100% / excellent
Sodium hydroxide 5% / excellent
Sodium hypochlorite 5% / excellent
H2O 100% / excellent
Ethanol 100% / excellent
certificate 1 en
(30-11-21)
certificate 2 en
(30-11-21)
statement 1 en
(30-11-21)
statement 2 en
(30-11-21)
Ab- / Desorption kinetic (VDI 2083 part 20 draft) Chemical: H2O2
H2O2 vapor concentration: 50 +/-20 ppm(V)
Exposure duration: 60 min
Air exchange rate (aeration): 100 1/min
k-value: / 0 min
Classification: / non-absorptive
certificate 1 en
(30-11-21)
statement 1 en
(30-11-21)
Riboflavin test (VDMA information leaflet) Based on VDMA information leaflet
Result: / excellent
certificate 1 en
(30-11-21)
statement 1 en
(30-11-21)
Particle emission (VDI 2083 part 17) reel-on-disc test:
counter specimen: PA6
single measuring track: 250 mm
velocity: 150 mm/s
normal force: 300 N
ISO 14644-1 / ISO Class 5
US FED 209E / US Class 100
certificate 1 en
(30-11-21)
statement 1 en
(30-11-21)