Report No. | Manufacturer | Product Name | Subject of Test (Result) |
---|---|---|---|
KN 1002-507 | Knauf Insulation GmbH | Ceiling system Heradesign superfine | Outgassing (VDI 2083 part 17) Particle emission (VDI 2083 part 9.1) |
KN 1002-507 | Knauf Insulation GmbH | Ceiling system Heradesign micro | Outgassing (VDI 2083 part 17) Particle emission (VDI 2083 part 9.1) |
OC 1005-524 | OCTANORM-Vertriebs-GmbH für Bauelemente | Al-composite-panels C826 | Chemical resistance (VDI 2083 part 17) |
OC 1005-524 | OCTANORM-Vertriebs-GmbH für Bauelemente | Ceiling type D40_1 | Expertise Particle emission (VDI 2083 part 9.1) |
OC 1005-524 | OCTANORM-Vertriebs-GmbH für Bauelemente | Partition wall type I1 and D1 | Expertise Particle emission (VDI 2083 part 9.1) |
SI 1103-544 | Sika AG | Sealant Sikaflex PRO-3 (i-Cure) | Biological resistance (ISO 846) Outgassing (VDI 2083 part 17) |
SI 1103-544 | Sika AG | Wall coating Sikagard-Wallcoat N | Biological resistance (ISO 846) Outgassing (VDI 2083 part 17) |
SI 1103-544 | Sika AG | Wall coating Sikagard-206 W | Biological resistance (ISO 846) |
SI 1103-544 | Sika AG | Wall coating Sikagard-216 W | Biological resistance (ISO 846) |
SI 1103-544 | Sika AG | Sealant Sikaflex-11 FC+ | Biological resistance (ISO 846) Outgassing (VDI 2083 part 17) |
KN 1202-589 | Knauf AMF GmbH & Co. KG | Ceiling system THERMATEX Alpha | Particle emission (VDI 2083 part 9.1) |
KN 1203-591 | Knauf Insulation GmbH | ceiling system Heradesign soft | Particle emission (VDI 2083 part 9.1) |
SI 1204-593 | Sika AG | Floor covering Sikafloor-264 Thixo | Particle emission (VDI 2083 part 17) |
TA 1206-602 | Tarkett AB | Floor covering Standard Plus | Outgassing (VDI 2083 part 17) Particle emission (VDI 2083 part 17) |
TA 1206-603 | Tarkett AB | Floor covering Primo Premium | Outgassing (VDI 2083 part 17) Particle emission (VDI 2083 part 17) |
KN 1202-589 | Knauf AMF GmbH & Co. KG | Ceiling system THERMATEX Alpha ONE | Particle emission (VDI 2083 part 9.1) |
KN 1202-589 | Knauf AMF GmbH & Co. KG | Ceiling system THERMATEX Acoustic | Particle emission (VDI 2083 part 9.1) |
KN 1202-589 | Knauf AMF GmbH & Co. KG | Coating AMF Acoustic Range coating (white) | Chemical resistance (VDI 2083 part 17) |
KN 1202-589 | Knauf AMF GmbH & Co. KG | Ceiling system THERMATEX Thermaclean S | Particle emission (VDI 2083 part 9.1) |
OW 1003-518 | Odenwald Faserplattenwerk GmbH | Ceiling system OWAtecta S 22 with lighting OWA-Opal / OWA-Opa E | Particle emission (VDI 2083 part 9.1) |
Filters
Text
Suitable for use in cleanroom areas of air cleanliness class ... according to ISO 14644-1*
- All ISO Classes (355 Hits)
- ISO Class 1 (48 Hits)
- ISO Class 2 or better (75 Hits)
- ISO Class 3 or better (99 Hits)
- ISO Class 4 or better (154 Hits)
- ISO Class 5 or better (178 Hits)
- ISO Class 6 or better (185 Hits)
- ISO Class 7 or better (187 Hits)
- ISO Class 8 or better (189 Hits)
- ISO Class 9 or better (189 Hits)
Subject Of Test
- All (355 Hits)
- Ab- / Desorption kinetic (VDI 2083 part 20 draft) (16 Hits)
- Air permeability (1 Hits)
- Biological resistance (ISO 846) (56 Hits)
- Chemical resistance (VDI 2083 part 17) (34 Hits)
- Cleanability (VDI 2083 part 17) (13 Hits)
- Electrical Resistance (acc. to DIN EN 61340-2-3, DIN EN 61340-3-2 and DIN EN 61340-3-1) (4 Hits)
- ESD behaviour (DIN EN 61340-5-1) (6 Hits)
- Expertise (23 Hits)
- Microbicidity (ISO 22196) (9 Hits)
- Outgassing (VDI 2083 part 17) (108 Hits)
- Outgassing (VOC) (16 Hits)
- Particel emission (ISO 14644 part 14) (51 Hits)
- Particle emission (VDI 2083 part 17) (113 Hits)
- Particle emission (VDI 2083 part 9.1) (54 Hits)
- Riboflavin test (VDMA information leaflet) (65 Hits)
Categories
- All (1496 Hits)
- Cleanroom Facilities (534 Hits)
- Automation Components (282 Hits)
- Working Place and Operator (147 Hits)
- Materials (207 Hits)
- Process Equipment (78 Hits)
- Services (10 Hits)
- Energy Supply (238 Hits)