5-fold endeffector 300 mm / manufacturing date: 7/2023 / weight: 2.6 kg
Company
Rena Technologies GmbH
Am Fohrenwald 1
78087 Mönchweiler
Contact Person
Angela Pfeffer
Phone
+4977239313459
Email
angela.pfeffer@rena.com
Website
Test Object
5-fold endeffector 300 mm
manufacturing date: 7/2023
weight: 2.6 kg
Q-Id
RE 2309-1458
Year
2023
Comments
Category
Positioning Systems
Tests And Results
Subject of Test
Parameter
Assessment for / Results
Documents
(valid to)
Particel emission (ISO 14644 part 14)
Vaccum pump: eingeschaltet / switched on
Cycle time: t = 50 s
Operating pressure: p = 4 bar
ISO 14644-1
/
ISO Class 1
certificate 1 en
(10-11-28)
certificate 1 de
(10-11-28)
statement 1 de
(10-11-28)
statement 1 en
(10-11-28)
Vaccum pump: ausgeschaltet / switched off
Cycle time: t = 50 s
Operating pressure: p = 4 bar
ISO 14644-1
/
ISO Class 1