Company
Polyflor Limited
Radcliffe New Road
M45 7NR Manchester
Contact Person
Graham King
Phone
0161 767 1111 Ex 1333
Email
gking@polyflor.com
Website
Test Object
Palettone PUR
2.0 mm
Urban Air
Q-Id
PO 1711-964
Year
2017
Comments
Category
Materials
Tests And Results
Subject of Test
Parameter
Assessment for / Results
Documents
(valid to)
Particle emission (VDI 2083 part 17)
Reel-on-disc test vs. PA6
velocity 0.45 m/s
normal force 300 N
ISO 14644-1
/
ISO Class 4
certificate 1 en
(04-12-22)
QLogo 1 en
(04-12-22)
QLogo 2 en
(04-12-22)
statement 1 en