TESTED DEVICE®

No image available!

Company

Tarkett AB
 
Ronnebyhamn
37281 Ronneby

Contact Person

Robin Carlsson
Phone
Email robin.carlsson@tarkett.com
Website

Test Object

iQ Optima
manufacturing date: 11/14/2021
batch number: 3101054694
Q-Id TA 2112-1288
Year 2022
Comments color: 857
Category Wall / Ceiling / Floor

Tests And Results

Subject of Test Parameter Assessment for / Results Documents
(valid to)
Particle emission (VDI 2083 part 17) reel-on-disc test:
counter specimen: PA6
Single measuring section: 250 mm
Velocity: 150 mm/s
normal force: 300 N
ISO 14644-1 / ISO Class 5
certificate 1 en
(13-04-27)
statement 1 en
(13-04-27)
Outgassing (VDI 2083 part 17) Substance group (x): VOC
SER 23°C / < 2.8 x 10^-10 g/m²s
SER 90°C / 3.2 x 10^-8 g/m²s
ISO-ACCm Class (x) / < -9.6 (based on 23°C)
certificate 1 en
(13-04-27)
statement 1 en
(13-04-27)
Substance group (x): SVOC
SER 23°C / < 2.8 x 10^-10 g/m²s
SER 90°C / < 1.7 x 10^-9 g/m²s
ISO-ACCm Class (x) / < -9.6 (based on 23°C)
Substance group (x): Amines
SER 23°C / < 2.8 x g/m²s
SER 90°C / < 1.7 x 10^-9 g/m²s
ISO-ACCm Class (x) / -- (based on 23°C)
Substance group (x): Organophosphates
SER 23°C / < 2.8 x g/m²s
SER 90°C / < 1.7 x 10^-9 g/m²s
ISO-ACCm Class (x) / -- (based on 23°C)
Substance group (x): Siloxanes
SER 23°C / < 2.8 x g/m²s
SER 90°C / 3.3 x 10^-9 g/m²s
ISO-ACCm Class (x) / -- (based on 23°C)
Substance group (x): Phthalates
SER 23°C / < 2.8 x g/m²s
SER 90°C / < 1.7 x g/m²s
ISO-ACCm Class (x) / -- (based on 23°C)