Manufacturer/company:
Lot 37631 & 37632, Jalan 6/37A Taman Bukit Maluri,
Kuala Lumpur
Malaysia
-
-
-
| Name of test piece/s | Flowshield ESD BVG |
|---|---|
| Project number | TR 2409-1559 |
| Created on | 09/23/2025 |
| Valid until | 11/29/2029 |
| Test type | Outgassing Behavior (VOC/SVOC)) |
| Classfication | ISO-ACCe/m-Class (x) at 23°C-7 bis -7,9 |
| Outgassing behvaior VOC/SVOC (ISO 14644-8, -15; ISO 16000-6, -9, -11, -25; VDI 2083 Part 17) | |||
|
Contaminant Category (x) |
SERa1) 23 °C | SERa1) 90 °C [g/m²*s] |
ISO‑ACCm Class (x) based on 23° C |
|
VOC |
4.2 x 10-8 | >> 7.9 x 10-4 |
-7.4 |
|
SVOC |
< 2.8 x 10-10 | Due to overload of the analytical system no quantitative result can be reported |
<-9.6 |
|
Amines |
< 2.8 x 10-10 |
-- |
|
|
Organophosphates |
< 2.8 x 10-10 |
-- |
|
|
Siloxanes |
5.9 x 10-10 |
-- |
|
| Phthalates | < 2.8 x 10-10 |
-- | |