Logo

Manufacturer/company:

Dauphin HumanDesign Group GmbH & Co. KG

Espanstraße 36
Offenhausen
Germany

Number of projects
7
Number of test pieces
19
Phone

-

Email

-

Website

www.dauphin.de

Documents

Urkunde ESD
Valid until 15.08.2026
Bescheinigung ESD
Valid until 15.08.2026

Test piece

Name of test piece/s Tec classic work chair medium backrest with foot ring ST mechanism, Madrid black (013.033)
Project number DA 2105-1234
Created on 08/24/2024
Valid until 08/15/2026
Test type testtype.electrical_resistance_chair
Classfication Grenzwert:fulfilled
testtype.electrical_resistance_chair

Electrostatic resistance (IEC 61340-2-3, -5-1)

Test procedure

Test voltage
[V]

Average resistance to the groundable (Rgp)

[Ω]

Compliance with limit values ​​according to DIN EN 61340-5-1

Backrest

10

4.9 x 105

fulfilled*

Seat 
point 1

10

3.6 x 105

fulfilled*

Seat 
point 2

10

3.5 x 105

fulfilled*

Seat
point 3

10

3.1 x 105

fulfilled*