Logo

Manufacturer/company:

GIMATIC S.r.l.

Via Enzo Ferrari, 2/4
Roncadelle - Brescia
Italy

Number of projects
4
Number of test pieces
13
Phone

-

Email

-

Website

http://www.gimatic.com/

Documents

No documents found

Test piece

Name of test piece/s Long stroke parallel gripper MPLM3240
Description Lot number: ODL-Z01271; size: 32; stroke: 40 mm
Project number GI 2003-1164
Created on 05/22/2025
Valid until 10/20/2025
Test type Particle emission (ISO 14644-1, -14)
Classfication Suitability for air cleanliness class: (ISO-Class):5
Particle emission (ISO 14644-1, -14)

Particle emission (ISO 14644-1, -14)

Test parameter(s)

Air Cleanliness Class

Control unit: supplied by the customer
Cycle time: 2.0 s
(1.0 s for opening; 1.0 s for closing)
Working gripper time per cycle: 1.06 s
Load: none


5


 

Overall result


Lubricant is clearly visible on the exterior. Therefore, use of the test piece in clean/hygienic areas is considered to be critical.

Please note: Transport damages, incorrect installation, oil leakage, aging behavior, corrosion etc. can influence the test result.