Test piece

Name of test piece/s Aseptic Extreme Rec. White 595x595mm 45W 840 PMMA82 + Glass
Description Size: 600 x 600 mm
Project number CL 2507-1656
Created on 09/02/2025
Valid until 06/06/2030
Test type Particle emission (ISO 14644-1, -14)
Classfication Suitability for air cleanliness class: (ISO-Class):1
Particle emission (ISO 14644-1, -14)

Particle emission (ISO 14644-1, -14)

Test parameter(s)

Air Cleanliness Class

Structure-borne noise = approx. 50 Hz

1

Overall result

1


It must be pointed out, that according to ISO 14644-1 cleanrooms classes 1 to 5 have a high filter occupancy, with the result that large-surface ceiling/lighting systems cannot be used in some cases. Cleanrooms with a horizontal displacement flow form an exception to this.
The test result may be influenced by the surrounding ceiling/lighting system, in particular the material pairing between the light and ceiling frame, as well as other assembly accessories. Particle emission behavior should be re-assessed in the respective assembly situation.
Please note: Transport damages, incorrect installation, aging behavior, corrosion etc. can influence the test result.